Aruba 4100i 12-port 1GbE (8-port Class 4 POE and 4-port Class 6 POE) 2-port SFP+ DIN Mount Switch (JL817A)
|
Description
|
4x ports 100M/1G BaseT Class 6 PoE ports supporting up to 60W per port
8x ports 100M/1G BaseT Class 4 PoE ports supporting up to 30W per port
|
2x 1/10G SFP ports
|
Supports PoE Standards IEEE 802.3af, 802.3at and 802.3bt (up to 60W)
|
1x USB-C Console Port
1x RJ Console
1x USB Type A Host port
1x Alarm socket
2x DC power socket
|
Power Supplies
|
Field replaceable Industrial DIN Rail Power Supplies
|
Supported PSUs: JL819A, JL820A and JL821A
Supported 2 PSU with redundancy, non sharing
|
See external PSU specification table for available PoE power
|
Fans
|
Fanless
|
Physical Characteristics
|
Dimensions
|
(H) 160 mm x
(W) 113 mm x
(D) 162.9 mm (173.5 mm w/DIN Rail Bracket)
[6.3" x 4.4" x 6.4"(6.8" w/DIN Rail Bracket)]
|
Weight
|
3.84 kg (8.46 lbs)
|
Mounting And Enclosure
|
Cable management kit included. 2-post rack mounting kit included.
4-post rack mounting kit available separately
|
Additional Specifications
|
CPU
|
Dual Core ARM Cortex A9 @ 1016 Mhz
|
Memory And Flash
|
4 GB DDR3
32 GB eMMC
|
Packet Buffer
|
12.38MB (4.5MB Ingress/7.875MB Egress)
|
Performance
|
Model Switching Capacity
|
up to 64 Gbps
|
Model Throughput Capacity
|
up to 46 Mpps
|
Average Latency (LIFO-64-bytes packets)
|
1 Gbps: 2.390µSec , 10 Gbps: 2.038µSec
|
Switched Virtual Interfaces (dual stack)
|
1G: 5.32 µSec
10G: 1.48 µSec
25G: 2.78 µSec
40G: 1.31 µSec
100G: 1.42 µSec
|
IPv4 host table (ARP)
|
756
|
IPv6 host table (ND)
|
576
|
IPv4 unicast routes
|
576
|
IPv6 unicast routes
|
576
|
MAC Table Size
|
8192
|
IGMP Groups
|
512
|
MLD groups
|
512
|
IPv4/IPv6/MAC ACL entries (ingress)
|
256 / 128 / 256
|
Environment
|
Operating temperature
|
-40°C to 60°C, 0m/s (-40°F to 140°F, 0 LFM)
-40°C to 70°C, 0.2m/s (-40°F to 158°F, 40 LFM)
-34°C to 75°C, 1m/s (-29.2°F to 167°F, 200 LFM)
|
Non-Operating Storage relative humidity
|
5% to 95%, non-condensing
|
Max Operating Altitude
|
up to 4.2 km (13800 ft) Max
|
Max non-operating Altitude
|
4.6 km (15000 ft) Max
|
Electrical Characteristics
|
Frequency
|
N/A
|
AC voltage
|
Refer to the PSU specification table
|
DC Input Voltage
|
54V (switch input voltage, provided by JL819A,
JL820A, JL821A)
|
Current
|
JL820A- max 8A (360W PoE)
JL819A, JL821A- max 4.4A (180W PoE)
|
Maximum heat dissipation BTU/hr
|
With JL819A PSU:
89 BTU/hr at 230V - Room temperature (25°C)
With JL820A PSU:
95 BTU/hr at 230V - Room temperature (25°C)
With JL821A PSU:
94 BTU/hr at 48V - Room temperature (25°C)
|
Power Consumption
(JL819A, JL820A- 230VAC)
(JL821A- 48VDC)
|
With JL819A PSU:
Idle: 22W
100% Traffic Rate: 26W
100% Traffic Rate (w/ heater): 55W
With JL820A PSU:
Idle: 24W
100% Traffic Rate: 28W
100% Traffic Rate (w/ heater): 57W
With JL821A PSU:
Idle: 22W
100% Traffic Rate: 27W
100% Traffic Rate (w/ heater): 56W
*Heater will only turn on at extreme low
temperature condition
|
Safety
|
Europe:
EN 60950-1:2006 + A11:2009 + A1:2010 +
A12:2011 + A2:2013
EN 62368-1, Ed.2:2014
North America:
UL 62368-1, 2nd Edition
CAN/CSA C22.2 No. 62368-1-14
Worldwide:
IEC 60950-1:2005 Ed.2 + Am 1:2009 + A2:2013
IEC 62368-1:2014
EN/IEC 60825-1:2014 Class 1
UL/IEC 61010-2-201
GB 4943.1:2011
CNS 14336-1
K 60950-1
|
EMC
|
Europe:
EN 55011:2010/CISPR 11, Class A
EN 55032:2015/CISPR 32, Class A
EN 55035:2017/CISPR 35
EN 61000-3-2:2014, Class A
EN 61000-3-3:2013
US:
FCC CFR 47 Part 15: 2018 Class A
Canada:
ICES-003 Class A
Japan:
VCCI Class A
Taiwan (BSMI)
CNS 13438 Class A
Korea
KN 35:2015
Korea
KN 32 Class A
Aus/NZ
AS/NZS CISPR 32 Class A
Worldwide:
VCCI Class A
CISPR 11 Class A
CISPR 22 Class A
|
Lasers
|
EN 60825-1:2007 / IEC 60825-1:2007 Class 1
Class 1 Laser Products / Laser Klasse 1
(Applicable for accessories - Optical Transceivers only
|
Industry Specific Compliance
|
Industrial
|
EN 61000-6-2 Industrial Immunity
EN 61000-6-4 Industrial Emissions
EN 61000-6-1 Light Industrial Immunity
|
Power Substation
|
IEEE 1613 Electric Power Stations
Communications Networking
EN/IEC 61850-3 Electric Substations
Communications Networking
|
Railway Application
|
EN 50121-3-2 Railway - Apparatus for Rolling Stock
EN 50121-4 Railway - Signaling and Telecommunications Apparatus
EN 50155/IEC 60571 - Railway applications, Rolling stock, Electronic equipment
|
Traffic Control System
|
NEMA TS 2-2016
|
Protection Standard
|
EN 60529 IP30
|
Immunity
|
Generic
|
EN 55035, CISPR 35, KN35
|
EN
|
EN 55035, CISPR 35
|
ESD
|
EN 61000-4-2 (air - 15kV, contact - 8kV)
|
Radiated
|
EN 61000-4-3 (10V/m UTP, 20V/m STP)
|
EFT/Burst
|
EN 61000-4-4
4kV (1kV UTP, 4kV STP) using:
JL819A, JL820A with SPD2-300-2P0-R surge protector
JL821A with SPD2-150-2P0-R surge protector needed.
Without surge protector and STP:
JL819A or JL820A PSU: 2kV
JL821A PSU: 1kV
|
Surge
|
EN 61000-4-5
2kV/4kV(UTP) using:
JL819A, JL820A with SPD2-300-2P0-R surge protector
JL821A with SPD2-150-2P0-R surge protector
Without surge protector:
JL819A or JL820A PSU: 1kV/2kV
JL821A PSU: N/A
|
Conducted
|
EN 61000-4-6 (3Vrms UTP, 10Vrms STP)
|
Power Frequency Magnetic Field
|
EN 61000-4-8 (100A/m 1min,1000A/m 1sec)
|
Damped Oscillatory Magnetic Field
|
EN 61000-4-10 (100A/m)
|
Conducted CM Disturbances
|
EN 61000-4-16 (30V, Cont/300V, 1 sec)
|
Ripple Immunity DC Power
|
EN 61000-4-17 (10%)
|
Damped Oscillatory Wave
|
EN 61000-4-18 (2.5kV, 1MHz)
|
Voltage Dips and interruptions
|
EN 61000-4-29; EN 61000-4-11 (Level 3)
|
Harmonics
|
EN 61000-3-2, IEC 61000-3-2
|
Flicker
|
EN 61000-3-3, IEC 61000-3-3
|
Dynamics
|
Vibration
|
IEC 60068-2-6 & 64 (operation & nonoperation)
|
Shock
|
IEC 60068-2-27 (Operational Shock, 30G, 18ms, Half-Sine)
IEC 60068-2-27 (Non-operational Shock, 50G, 11ms, Trapezoidal)
IEC 60068-2-31 (Non-operational Free Fall, 100mm)
IEC 60068-2-31 (Non-operational Topple)
|
Railway Application
|
Compliance to EN 50155 (mounting) & IEC 61373
|
Mounting and Enclosure
|
Mounts to JL822A (3U DIN-to-Rack Bracket, puchased separately) which allows the switch to be mounted in an EIA/TIA standard 19" telco rack.
|
Switch can be directly installed on a DIN rail mounted to a suitable surface to withstand the weight of the switch and power supplies.
|
DIN rail mounting (included).
|
Can be mounted in 90-degree manner to present the cables exiting the side of the switch - see installation guide for details.
|
Wire
|
Power Input
|
AWG 14 up to 2m
|
Alarm connector
|
AWG 18-16
|
PoE Budget
|
User configurable PoE budget - If 2 external power supply units are used concurrently, please set according to PSU with lower PoE capacity.
JL819A
Below ambient 50°C: 180W
At ambient 60°C: 140W
At ambient 70°C: 80W
JL820A
Below ambient 50°C: 360W
At ambient 60°C: 320W
At ambient 70°C: 200W
JL821A
With PSU input = 48V-55V DC
Below ambient 50°C: 180W
At ambient 60°C and 70°C: 150W
With PSU input = 24V DC
Below ambient 70°C: 150W
With PSU input = 12V DC
Below ambient 60°C: 60W
At ambient 70°C: 50W
Does not support PSU Power Sharing. Refer to Installation & Getting Started Guide for the PoE budget setup.
|